Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Coaxial data communication line function.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words
MR-ECNP2-A(20pcs) PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance. Servo motor series: ultra low inertia, small capacity.
Rated output: 0.4kw.
Rated speed: 3000r/min.
Electromagnetic brake: No.
Power supply: 200V.
The rated speed is 3000r/min, the maximum speed is 6000r/min.
The maximum torque of 350% of the rated torque, high torque in the field of high rotation, only to support the HG-KR series products.
Built in absolute position encoder with high resolution.
Standard high resolution absolute position encoder (4194304p/rev (22bit)).
To achieve a higher accuracy of the positioning function.
Improve the environmental performance of HG-KR, HG-MR, HG-RR, HG-UR series of products using IP65. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 355KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.
MR-ECNP2-A(20pcs) Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-ECNP2-A(20pcs)&select=5