"Power: 55kw.
Voltage: 400V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time consumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy
HC-RFS203G2 1/9 "Servo motor series: low inertia, small capacity.
Rated output: 0.5kw.
Rated speed: 2000r/min.
Electromagnetic brake: No.
Oil seal: have.
Corresponding servo amplifier: MR-JE-10B/MR-JE-10A.
Support position control, speed control, torque control, push and press control.
Position control can use linear, arc interpolation controller, fixed size feed control, target position change and other rich functions.
The position control and torque control are realized by switching control mode.
The gain adjustment of servo can be simply performed by the advanced one key tuning function.
At the same time, it is also able to suppress the low frequency vibration of the manipulator by the advanced vibration suppression control II,
Shorten the time to complete the positioning, so as to achieve the production of the rhythm of the shortening. Express PCI bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
With external power supply function.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.
HC-RFS203G2 1/9 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HC-RFS203G2 1/9&select=5