Function: CPU module (internal service power supply).
Input and output points: 80 points.
Power supply capacity (DC5V power): 1100mA.
Power supply capacity (DC24V service power supply): 600mA.
Input / output mode: DC input (drain / source) / transistor (drain).
Input points: 40 points.
Output points: 40 points.
The new expansion module is more convenient!
Pioneer products with advanced built-in functions and rich extensibility
GT1150HS-QLBD
FX5U built-in analog, communication, high speed input and output,
By extending the board and adapter can be easily extended system.
In addition, through the high speed system bus,
Can maximize the role of the built-in intelligent functions of the expansion device.
Purpose: to operate, monitor, and change the parameters through the network.
Applicable frequency converter: FR-A700, FR-F700, FR-E700. Max input / output points: 60 points.
Power supply voltage: DC24V.
Input points: 36 points.
Output points: 24 points.
Output type: relay.
Power consumption (W): 35.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control. Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:0.20.
Optical data communication line.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
GT1150HS-QLBD Operation manual / Instructions / Catalog download link: