DC input.
Number of input channels: 2Ch.
DC5/12/24V input.
Maximum count rate: pulse/s 200k.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control
FX3UC-32MT-LT-2
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized.
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized. "Input points: 16 points.
Rated input voltage and frequency: DC24V.
Rated input current: TYP 7.0mA.
Response time: 0.1 ~ 70ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LED, can easily confirm the status of the ON/OFF.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, through the switch to switch to display the input and output number.
In addition, serial number tag in the front of the module, can be easily recognized. "
FX3UC-32MT-LT-2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX3UC-32MT-LT-2&select=5