Max input / output points: 80 points.
Power supply voltage: 24VDC.
Input points: 40 points.
Output points: 40 points.
Output type: relay.
Power consumption: 40W.
Weight (kg):1.2.
Size (WxHxD) mm:285x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation
FR-A540-45K-CH
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Motor series: low inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 1.0kw.
Rated speed: 3000rpm.
With the brake: without.
Shaft end: straight shaft.
Performance comparison of servo motor and stepping motor.
Stepper motor as an open-loop control system, and modern digital control technology has the essential link.
In the current domestic digital control system, stepping motor is widely used.
With the emergence of digital AC servo system, AC servo motor is more and more used in digital control system.
In order to adapt to the development trend of digital control, most of the motion control system adopts stepping motor or full digital AC servo motor as executive motor.
Although they are similar in control mode (pulse train and directional signal), there are great differences in performance and application.
The use performance of the two are compared.PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
FR-A540-45K-CH Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-A540-45K-CH&select=5