Motor series: medium inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 0.85kw.
Rated speed: 1000rpm.
With a brake band.
Shaft end: straight shaft.
The structure of the AC servo motor stator is basically similar to the capacitor split phase single-phase induction motor.
The stator is provided with two positions of 90 degrees of mutual difference of the winding, one is the excitation winding Rf, it is always connected to the AC voltage Uf;
The other is to control the winding L, which is connected to the control signal voltage Uc
A985GOT-TBA
So the AC servo motor, also known as the two servo motor. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 1.5kw.
SLD converter rated current: 10.5A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down.
A985GOT-TBA Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A985GOT-TBA&select=5