Input and output points: 48 points.
DC power supply: DC24V.
Input points: 24 points.
Output points: 24 points.
Output form: transistor output (source).
Weight: 0.85kg.
Input signal voltage: DC24V.
FX2N series expansion unit
Expansion unit is an input and output expansion device with a built-in power supply.
As with the basic unit, the extension unit can be connected to a variety of input and output and special extension equipment
A1SJ71BR11
Can connect to FX3GA/FX3G, FX3GE and FX3U.
AC power model, the built-in maximum DC24V 250mA/460mA supply power.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit can reach 1ms.
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis.
Extended function expansion board and special adapter,
Data links and communication with external serial devices. Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 line /2 line type.
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. Input and output points: 256 points.
Input / output data points: 256 points.
Program capacity: 6k.
Basic command processing speed (LD command) s:1.0.
Internal storage RAM memory capacity: 16k.
Optical data communication line function with power supply.
Input / output data control mode conversion.
It is possible to enter the control of the output data as the following 3.
(1) input: direct mode, output: direct mode.
(2) input: I/O impression update mode, output: direct mode.
(3) input: I/O impression update mode, output: I/O impression update mode.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
A1SJ71BR11 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A1SJ71BR11&select=5