Protective film for 5.7 inch screen.
Transparent, 5.
Applicable model: GT11. MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.2kw.
Interface type: SSCNET type III fiber communication.
Power specification: single phase AC200V.
High speed serial communication between the SSCNET and the servo amplifier by using the fastest up to 0.44ms communication cycle,
A fully synchronous control system can be constructed
NZ2GF2B-60TCRT4
It is only necessary to insert the special optical fiber into the joint to form SSCNET III network, which greatly reduces the wiring work and reduces the possibility of false wiring.
Due to the adoption of the optical fiber communication, the anti noise ability can be greatly improved and the long distance wiring of 50 meters (maximum 800 meters x 16 axes) can be realized.
A servo amplifier to meet the full closed loop control function MR-J3-B-RJ006.
Suitable for mechanical servo optimization and adjustment!
More advanced optimization adjustment function and control function to maximize mechanical properties. MITSUBISHI inverter series: FR-A800.
Voltage level: three phase 400V.
Power: 400kw.
SLD converter rated current: 962A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
To maximize the performance of the motor.
Advanced auto tuning function.
The newly developed PM motor auto tuning feature can be used to operate other manufacturers of PM motors (Yong Ci synchronous motors) in the sensorless state.
Not only can drive MITSUBISHI induction motor and PM motor, but also can drive other manufacturers of induction motor and PM motor.
This means that you can reduce the cost of inventory and supplies.
If the PM motor is produced by a IPM motor or other company using MM-CF, the starting torque is limited to 50%,
Even after tuning is not simple to use and positioning control of zero speed torque) induction motor and permanent magnet motor can be combined freely. JEMANET (OPCN-1) interface unit from the station.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
NZ2GF2B-60TCRT4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=NZ2GF2B-60TCRT4&select=5