MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 0.4kw.
Built in positioning function.
Voltage: 3 phase AC200VAC or single phase AC230V.
Compatible with "MR-J2S- CP-S084" - servo amplifier and interface unit "MR-J2S-TO1" positioning by CC-Link
Simply setting the point table.
AC servo can be used as the driving source of the field network.
Using servo amplifier built-in positioning function, position data and speed data, you can set the CC-Link
MR-J3-22KT4
Start, stop and display can also be transmitted through the CC-Link.
Serial communication reduces wiring.
AC servo distributed control system can be easily constructed.Cable length: 3m.
For connection between QnA/A/FXCPU (D-SUB25 pin connector) and GOT.
Connection between serial communication unit (AJ71QC24-R4) and GOT.
Applicable models: GT10, GT21. Servo motor series: low inertia, low power.
Rated output: 0.75kw.
Rated speed: 3000r/min.
Electromagnetic brake: No.
Shaft end specification: Standard (straight axis).
Features: low inertia is widely used in general machinery.
IP level: IP65.
Application example:
1, belt drive.
2, industrial robots.
3, assembly machinery.
4, industrial sewing machine.
5, X-Y working table.
6, food processing machinery.
7, semiconductor manufacturing equipment.
8, knitting machine and embroidery machine.
Rotary servo motor.
Numerous motor series and wide motor power range can be used to meet different applications.
The protection level of the HF-KP/HF-MP/HC-LP/HC-RP/HC-UP servo motor to improve the environmental safety is IP65 (except the shaft part). MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 30kw.
SLD converter rated current: 62.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control.
MR-J3-22KT4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J3-22KT4&select=5