MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation
IS74-5.5K-CHT Program 1 channel connection, AnCPU/QnACPU use.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Analog input channel number: 8CH.
Cold end compensation precision.
Available thermocouple: -.
Available temperature resistance: Pt100, JPt100, Ni100, Pt50.
Resolution: 0.1.
Conversion speed: 10ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector.
output
The temperature measurement value (16 bit''signed binary): 2000 ~ 8500.
Zoom value (16 bit with symbol binary).
No program can perform conversion operations, scaling
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data. The analog quantity input data can be stored and maintained before and after the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data. Such as motor testing equipment used in this function.
Control instructions from a programmable controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time.