MITSUBISHI
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet

MITSUBISHI RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet

Brand: MITSUBISHI
Product model: RJ71GF11T2
Name: Communication module
Sort: PDF datasheet
File language: English
File size: 42.57MB
230.4kbps Max., RS-422/485 2 channel.
When using the serial communication module, it is only necessary to select from the communication protocol library of engineering software,
Can carry out data communication support MODBUS general agreement.
2 channels are supported 230.4kbps, communication can fully play the performance of the matching equipment RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet RJ71GF11T2 Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion. Can be divided into 16 groups, with its heating up to the time,
Reducee the overall system in heating up the waste of energy RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet.
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply ccapacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set RJ71GF11T2 datasheet PDF catalog RJ71GF11T2 PDF datasheet.
Can be divided into 5 groups.