Operation control mode: stored procedure repeated operation.
Built in IE CC-Link.
Input / output points: 4096 points.
Program capacity: 320K.
Program capacity of up to 1200K.
Multi CPU system for high precision motion control.
The built-in CPU module support 2 Gigabit Network port.
Database functions to facilitate data management RD62D2 datasheet PDF catalog RD62D2 PDF datasheet.
Extended SRAM card with built-in security function
RD62D2
Can be carried out a variety of motion control (position, speed, torque, advanced synchronous control, etc.).
In line with the international safety standards (13849-1 PL e ISO, IEC 61508 SIL 3) security CPU.
The most suitable for C/C++ language programming from the computer / computer environment for transplantation RD62D2 datasheet PDF catalog RD62D2 PDF datasheet.
Standard interface.
The programmable controller CPU module has standard Ethernet port, USB port, SD card slot.
Ethernet port and USB port can be used to communicate with the corresponding peripheral devices,
SD memory card slot can be used to record data, databases and other data storage.
In addition, the expansion of the SRAM card can be used for the expansion of the capacity of the soft element / tag memory and used as a hardware security key RD62D2 datasheet PDF catalog RD62D2 PDF datasheet. Analog input channel number: 4CH.
Available thermocouple: -.
Available temperature resistance: PT100, JPt100.
Sampling period 4CH: 250ms/500ms.
Control output cycle: 0.5s ~ 100.0s.
Input impedance: 1M.
Input filter (0: input filter OFF): 0 ~ 100s.
Sensor compensation value setting: the full range of the input range of the negative terminal to the full range of the input range.
Sensor input when the action: according to the scale of the processing.
Temperature control mode: ON/OFF PID pulse or 2 position control
Heater disconnection detection specification: there.
External wiring connection mode: 18 point screw terminal.
IQ-R MELSEC series of temperature control module to achieve a high stability and response to the temperature control.
Divided into Thermocouple Input, temperature resistance input two types of input,
These two kinds of input types are distinguished by the function of the detection of the broken line with / without heater.
Module binding function.
Combined with the use of up to 64 sets of temperature control module for temperature control. Can be combined with the function of the following two points.
Heating function between modules.
Peak current suppression function between modules.
By cooperating with the time of arrival of a number of loops, the average temperature is controlled.
Can realize the uniform temperature control, avoid partial burning control object,
Part of the phenomenon of thermal expansion. Can be divided into 16 groups, with its heating up to the timee,
Reduce the overall system in heating up the waste of energy RD62D2 datasheet PDF catalog RD62D2 PDF datasheet.
Peak current suppression function between modules
By the time staggered output transistor, suppressing peak current.
The power supply ccapacity of the equipment can be reduced by setting a larger channel and a smaller channel of the heater in the same set RD62D2 datasheet PDF catalog RD62D2 PDF datasheet.
Can be divided into 5 groups.