Program capacity: 124 K step.
Input / output points: 4096 points.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 496 KB.
Support USB and RS232.
High performance CPU plus a set of rich and powerful process control instructions.
High speed and high precision machine control by multi CPU QG69L datasheet PDF catalog QG69L PDF datasheet.
By parallel processing of the linear and multi CPU high-speed communication (cycle 0
QG69L88ms) of the parallel control program, the high speed control.
Multi CPU high speed communication cycle and motion control synchronization, so it can achieve the maximization of computing efficiency.
In addition, the latest movement control CPU in performance is 2 times the previous model,
To ensure high speed and high accuracy of the machine control QG69L datasheet PDF catalog QG69L PDF datasheet.
The position signal of the first axis servo amplifier, which is used on the motion CPU, is used as a trigger,
Starting from the programmable controller CPU to the second axis servo amplifier,
Time to output speed command of servo amplifier.
This time is the index of data transmission speed between CPU.Application: Q series QG69L datasheet PDF catalog QG69L PDF datasheet.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Add up to 3 additional units: safety relay module.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage function, the master can be connected to the CCH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication QG69L datasheet PDF catalog QG69L PDF datasheet.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment QG69L datasheet PDF catalog QG69L PDF datasheet. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)