FL-net (OPCN-2) Ver.1.00 interface.
10BASE5 use.Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps Q2MEM-1MBS datasheet PDF catalog Q2MEM-1MBS PDF datasheet.
CC-Link/LT from the station does not need any parameter settings
Q2MEM-1MBS
Only need to set up the transmission speed in the master module, you can use the remote I/O.
QJ61CL12 can be used as the main station of CC-Link/LT.Battery replacement.
Initial voltage 3.0V.
Base of large capacity battery.
Current capacity: 5000mAh.
Service life: 5 years.Program capacity: 252 K step.
Input / output points: 4096 points Q2MEM-1MBS datasheet PDF catalog Q2MEM-1MBS PDF datasheet.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 1008 KB.
Support USB and RS232.
Durable redundant CPU.
The position signal of the first axis servo amplifier, which is used on the motion CPU, is used as a trigger,
Starting from the programmable controller CPU to the second axis servo amplifier,
Time to output speed command of servo amplifier Q2MEM-1MBS datasheet PDF catalog Q2MEM-1MBS PDF datasheet.
This time is the index of data transmission speed between CPU.Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output.
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analoog Q2MEM-1MBS datasheet PDF catalog Q2MEM-1MBS PDF datasheet.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integratiion time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station Q2MEM-1MBS datasheet PDF catalog Q2MEM-1MBS PDF datasheet.