Input points: servo external signal 32 points, 8 axis.
Input mode: source / drain type.
Input and output points: 32 points.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card Q12DCCPU-V datasheet PDF catalog Q12DCCPU-V PDF datasheet
Q12DCCPU-V
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports.
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the change of the specified control data without any omission Q12DCCPU-V datasheet PDF catalog Q12DCCPU-V PDF datasheet.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.1 axes, open collector output type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output Q12DCCPU-V datasheet PDF catalog Q12DCCPU-V PDF datasheet.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control.
(the command pulse of the open collector positioning module is highest 200kpps.) Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particuular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces Q12DCCPU-V datasheet PDF catalog Q12DCCPU-V PDF datasheet.
Visualization of installation status.
Can monitor the safe output,, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start Q12DCCPU-V datasheet PDF catalog Q12DCCPU-V PDF datasheet.