Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption: 30VA.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter FR-HC2-30K datasheet PDF catalog FR-HC2-30K PDF datasheet.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module FR-HC2-30K
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation FR-HC2-30K datasheet PDF catalog FR-HC2-30K PDF datasheet.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard FR-HC2-30K datasheet PDF catalog FR-HC2-30K PDF datasheet.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Power: 0.4kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Total input and output points: 32 points.
Input points: 16 points.
Output points: 16 points.
Output type: relay output.
Power supply voltage: AC100-240V.
Input signal voltage: DC24V.
8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online channge the program will not lose the working hours or stop production operation FR-HC2-30K datasheet PDF catalog FR-HC2-30K PDF datasheet.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program FR-HC2-30K datasheet PDF catalog FR-HC2-30K PDF datasheet.
Related products
MITSUBISHI
hpfr
FR-HC2-H15K
MITSUBISHI hpfr FR-HC2-H15K
Power: 15kw. Voltage: 400V. The power factor
MITSUBISHI
hpfr
FR-HC2-H160K
MITSUBISHI hpfr FR-HC2-H160K
Power: 160kw. Voltage: 400V. The power factor
MITSUBISHI
hpfr
FR-HC2-7.5K
MITSUBISHI hpfr FR-HC2-7.5K
Power: 7.5kw. Voltage: 200V. The power factor
MITSUBISHI
hpfr
FR-HC2-H400K
MITSUBISHI hpfr FR-HC2-H400K
Power: 400kw. Voltage: 400V. The power factor