MITSUBISHI A1S62TCRTBW-S2 datasheet PDF catalog A1S62TCRTBW-S2 PDF datasheet

Brand: MITSUBISHI
Product model: A1S62TCRTBW-S2
Name: Temperature control module
Sort: PDF datasheet
File language: English
File size: 1.60MB
Input points: 32 points.
Input voltage and current: 120V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
36 point terminal station A1S62TCRTBW-S2 datasheet PDF catalog A1S62TCRTBW-S2 PDF datasheet.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A1S62TCRTBW-S2 datasheet PDF catalog A1S62TCRTBW-S2 PDF datasheet A1S62TCRTBW-S2
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A1S62TCRTBW-S2 datasheet PDF catalog A1S62TCRTBW-S2 PDF datasheet.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 iinputs and 6 output points A1S62TCRTBW-S2 datasheet PDF catalog A1S62TCRTBW-S2 PDF datasheet. A1SG60 is an empty cover that is used to plug in the unused I/O slot on the main board or on the extended board.
A1SG60 is a reserved dummy module I/O poinnt to PLC extended I/O system A1S62TCRTBW-S2 datasheet PDF catalog A1S62TCRTBW-S2 PDF datasheet.
With the switch on the module can be set to retain the I/O point,
Can set 16 points, 32 points, 48 points and 64 points.
Related products
MITSUBISHI
Temperature control module
A1S62TCTTBW-S2
MITSUBISHI Temperature control module A1S62TCTTBW-S2
Numer of channels: 2 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S62TCTT-S2
MITSUBISHI Temperature control module A1S62TCTT-S2
Numer of channels: 2 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S62TCRT-S2
MITSUBISHI Temperature control module A1S62TCRT-S2
Numer of channels: 2 channels. Sensing metho
MITSUBISHI
Temperature control module
A1S62TCRTBW-S2
MITSUBISHI Temperature control module A1S62TCRTBW-S2
Numer of channels: 2 channels. Sensing metho