The input and output module installation number: 5.
Can install module: iQ-R MELSEC series module.
DIN guide rail mounting adapter type: R6DIN1.
Size (H) * (32.5mm) * (W) * (D): * 245mm * 101mm.
Substrate module for mounting various modules of iQ-R MELSEC series.
CPU module could not be installed on the extended substrate module RV-12SD Series Manual RV-12SD Series Standard Specifications Manual
RV-12SD Series "The input and output module installation number: 12.
Can install module: MELSEC-Q series module.
DIN guide rail mounting adapter type: Q6DIN1.
Size (H) * (44.1mm) * (W) * (D): * 439mm * 98mm.
Substrate module for mounting various modules of MELSEC-Q series.
Extended use of Q series expansion substrates in the following extensions. "Analog input channel number: 8CH RV-12SD Series Manual RV-12SD Series Standard Specifications Manual.
Cold end compensation precision.
Available thermocouple: -.
Available temperature resistance: Pt100, JPt100, Ni100, Pt50.
Resolution: 0.1.
Conversion speed: 10ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector.
output
The temperature measurement value (16 bit''signed binary): 2000 ~ 8500.
Zoom value (16 bit with symbol binary) RV-12SD Series Manual RV-12SD Series Standard Specifications Manual.
No program can perform conversion operations, scaling
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data. The analog quantity input data can be stored and maintained before and after the trigger state through the function,
EEasy to determine the occurrence of the phenomenon and the collection of test data RV-12SD Series Manual RV-12SD Series Standard Specifications Manual. Such as motor testing equipment used in this function.
Control instructions from a programmablee controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time RV-12SD Series Manual RV-12SD Series Standard Specifications Manual.