MITSUBISHI QJ71FL71-T Manual QJ71FL71-T User's Manual

Brand: MITSUBISHI
Product model: QJ71FL71-T
Name: FL-net(OPCN-2) Interface Module
Sort: User's Manual
File language: English
File size: 3.66MB
Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic QJ71FL71-T Manual QJ71FL71-T User's Manual QJ71FL71-T
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Three-phase 3 wire type.
Measuring circuit number: 4 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc QJ71FL71-T Manual QJ71FL71-T User's Manual. .
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm QJ71FL71-T Manual QJ71FL71-T User's Manual.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control proocedures QJ71FL71-T Manual QJ71FL71-T User's Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down QJ71FL71-T Manual QJ71FL71-T User's Manual.
Related products
MITSUBISHI
FL-net module
QJ71FL71-T-F01
MITSUBISHI FL-net module QJ71FL71-T-F01
FL-net OPCN-2 Ver.2.00 interface. 10BASE5/1
MITSUBISHI
FL-net module
QJ71FL71-T
MITSUBISHI FL-net module QJ71FL71-T
FL-net OPCN-2 Ver.1.00 interface. 10BASE5/1
MITSUBISHI
FL-net module
QJ71FL71-B5
MITSUBISHI FL-net module QJ71FL71-B5
FL-net OPCN-2 Ver.1.00 interface. 10BASE5 u
MITSUBISHI
FL-net module
QJ71FL71-B2
MITSUBISHI FL-net module QJ71FL71-B2
FL-net OPCN-2 Ver.1.00 interface. 10BASE2 u