2 axes, open collector output type.
2 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types QD70D4 Manual QD70D4 User's Manual.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control QD70D4
(the command pulse of the open collector positioning module is highest 200kpps.) Output: 2 channels.
Input (resolution): 0~12000; -12000~12000; 0~12000; -16000~16000 QD70D4 Manual QD70D4 User's Manual.
Output DC0~20mA; DC-12~12V.
Conversion speed: 10ms/1 channel.
18 point terminal station.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller QD70D4 Manual QD70D4 User's Manual.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module. Control axis: maximum 8 axes.
Teaching running function: there (when using SV13).
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified loocation to stop the instruction,
Can be set in advance to stop the location QD70D4 Manual QD70D4 User's Manual.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / decelleration time QD70D4 Manual QD70D4 User's Manual.
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.