4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000;
Conversion speed of 80 s/1 channel.
18 point terminal station.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications QD62 Hardware Manual QD62 User's Manual.
Can also meet the needs of high speed, high precision control QD62
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs QD62 Hardware Manual QD62 User's Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields QD62 Hardware Manual QD62 User's Manual.
Can also be used in combination with the CPU module to achieve appropriate control.Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: N type (positive public end / negative public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is nott needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces QD62 Hardware Manual QD62 User's Manual.
Visualization of installation status.
Can monitor the safe output,, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start QD62 Hardware Manual QD62 User's Manual.