MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q3ACPU Manual Q3ACPU General Instruction Manual

MITSUBISHI Q3ACPU Manual Q3ACPU General Instruction Manual

Brand: MITSUBISHI
Product model: Q3ACPU
Name: Programmable Controller
Sort: General Instruction Manual
File language: English
File size: 5.67MB
MES interface module.
Need MX MESInterface software and CF card.
Easily connect production equipment and information system.
Through the excellent database sharing function, greatly reduce the cost of information.
By direct connection, the connection process of the enterprise system database (such as MES) is simplified Q3ACPU Manual Q3ACPU General Instruction Manual.
Module configuration is simple, without any programming Q3ACPU
The data can be monitored in the module side, when a user defined trigger condition occurs,
Will be read in the form of SQL text and send the specified data to the MES.
The network load can be reduced compared with the previous scheme which is based on the gateway PC to obtain / monitor the data.
Receive information from the MES, perform pre stored SQL tasks Q3ACPU Manual Q3ACPU General Instruction Manual.
In addition, the production instructions from the MES are also received,
The production information can be downloaded from the database, and the modification of the formula information can be conveniently carried out. For 32 point I/O. 0.5 square mm (AWG20).Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function Q3ACPU Manual Q3ACPU General Instruction Manual.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating mmodule has the function of preventing overheating and preventing over cooling Q3ACPU Manual Q3ACPU General Instruction Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q3ACPU Manual Q3ACPU General Instruction Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products