Brand: MITSUBISHI
Product model: Q2AHCPU-S1
Name: Programmable Controller
Sort: General Instruction Manual
File language: English
File size: 5.67MB
Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings Q2AHCPU-S1 Manual Q2AHCPU-S1 General Instruction Manual.
Only need to set up the transmission speed in the master module, you can use the remote I/O Q2AHCPU-S1
QJ61CL12 can be used as the main station of CC-Link/LT.Input: 4 channels.
Platinum resistance (Pt10; JPt100).
Conversion speed: 40ms/1.
Channel 18 point terminal.
Platinum thermal resistance (Pt100, JPt100).
Nickel thermal resistance (Ni100).
Shedding detection function Q2AHCPU-S1 Manual Q2AHCPU-S1 General Instruction Manual.
Conversion speed: 320ms/8 channel.
Inter channel isolation.
40 pin connector.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Reduce system downtime recovery time Q2AHCPU-S1 Manual Q2AHCPU-S1 General Instruction Manual.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameterss due to forgetting to replace the battery Q2AHCPU-S1 Manual Q2AHCPU-S1 General Instruction Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and otther planned downtime,
The data is lost due to battery depletion Q2AHCPU-S1 Manual Q2AHCPU-S1 General Instruction Manual.
The next time the power is turned on, the backup data will be automatically restored.
Related products
MITSUBISHI
Motion controller (upgrade)
Q170MCPU-S1
MITSUBISHI Motion controller (upgrade) Q170MCPU-S1
Axis of control: 16. Compact Q170MCPU integra
MITSUBISHI
Moving CPU unit
A73CPU-S1
MITSUBISHI Moving CPU unit A73CPU-S1
Multi axis positioning controller. Program ca
MITSUBISHI
Motion CPU module
Q173DCPU-S1
MITSUBISHI Motion CPU module Q173DCPU-S1
Upgraded version. Control axis: maximum 32 ax
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. Input /