371此ID下载地址不存在3--/downloadfile/261-MELSEC-QL-MELSEC-Communication-Protocol-Reference.pdf MITSUBISHI Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual

MITSUBISHI Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual

Brand: MITSUBISHI
Product model: Q26UDVCPU
Name: PLC
Sort: Reference Manual (Communication Protocal)
File language: English
File size: 0.00MB
Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual Q26UDVCPU
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.SRAM memory card.
RAM capacity: 2MB Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual. Input voltage range: AC100-120V/AC200-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other plannedd downtime,
The data is lost due to battery depletion Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual.
The next time the power is turned on, the backup data will be automatically restored.
Through the expansion of soft components,, more convenient to create the program Q26UDVCPU Communication Protocal Manual Q26UDVCPU Reference Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Related products
MITSUBISHI
General high speed CPU
Q13UDVCPU
MITSUBISHI General high speed CPU Q13UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General purpose CPU
Q26UDHCPU
MITSUBISHI General purpose CPU Q26UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Numer of