MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual

MITSUBISHI Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual

Brand: MITSUBISHI
Product model: Q24DHCCPU-LS
Name: PLC
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 3.16MB
Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual Q24DHCCPU-LS
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual. GI-62.5/125 optical cable.
Double ring.
Remote I/O net (remote I/O station).Control axis: up to 16 axes.
Interpolation function: linear interpolation (maximum 4 axis), arc interpolation (2 axis), spiral interpolation (3 axis).
PLC capacity: 60K step.
Can control the maximum 16 axis servo amplifier.
With the position control, speed control, torque control, advanced synchronous control and other rich control methods Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual.
The incremental synchronous encoder I/F and the symbol detection signal I/F are integrated in the 1 modules.
Capacity expansion can be expanded to PLC capacity 60K step (using Q170MSCPU-S1), the 7 layer of the substrate.
Combined with the servo amplifier to achieve safe torque off (STO).
Connect directly to the visual system produced by Ethernet through the COGNEX connection.
Connection SSCNET III /H main module LJ72MS15 can use the MELSEC-L series of input.
Output module, analog input and output module, high speed counter module.Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server cann handle multiple files, it can reduce the task of management and maintenance Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do noot have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution Q24DHCCPU-LS MELSAP-L Manual Q24DHCCPU-LS Programming Manual.
Related products
MITSUBISHI
C language CPU
Q24DHCCPU-VG
MITSUBISHI C language CPU Q24DHCCPU-VG
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q24DHCCPU-V
MITSUBISHI C language CPU Q24DHCCPU-V
Input / output points: 4096 points. Size side
MITSUBISHI
C language CPU
Q24DHCCPU-LS
MITSUBISHI C language CPU Q24DHCCPU-LS
Input / output points: 4096 points. Size side