1554此ID下载地址不存在3--/downloadfile/36-MELSEC-QLQnA-Programming-(PID-Control-88s).pdf MITSUBISHI Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual

MITSUBISHI Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual

Brand: MITSUBISHI
Product model: Q20UDEHCPU
Name: PLC
Sort: Programming Manual (PID Control Instructions)
File language: English
File size: 0.00MB
E81WH4W, QE83WH4W special transformer.
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual Q20UDEHCPU
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual.
For example, a module can be used to measure other loads from the control panel trunk.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual. Input: 4 channels.
Platinum resistance (Pt100; JPt100).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function oof preventing overheating and preventing over cooling Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q20UDEHCPU PID Control Instructions Manual Q20UDEHCPU Programming Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General purpose CPU
Q20UDHCPU
MITSUBISHI General purpose CPU Q20UDHCPU
Specification model: Q20UDHCPU. Input / outpu