MITSUBISHI Q173NCCPU-S01 Special Instructions Manual Q173NCCPU-S01 Strctured Programming Manual

Brand: MITSUBISHI
Product model: Q173NCCPU-S01
Name: CPU
Sort: Strctured Programming Manual (Special Instructions)
File language: English
File size: 5.69MB
Output: 6 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000.
Output: DC-12V~12V; 0~22mA.
Conversion speed: 6ms/ channel.
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark Q173NCCPU-S01 Special Instructions Manual Q173NCCPU-S01 Strctured Programming Manual Q173NCCPU-S01
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier Q173NCCPU-S01 Special Instructions Manual Q173NCCPU-S01 Strctured Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module. Input: 4 channels.
Platinum resistance (Pt100; JPt100) Q173NCCPU-S01 Special Instructions Manual Q173NCCPU-S01 Strctured Programming Manual.
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same timee to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q173NCCPU-S01 Special Instructions Manual Q173NCCPU-S01 Strctured Programming Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q173NCCPU-S01 Special Instructions Manual Q173NCCPU-S01 Strctured Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.