Connect to read and write 2Ch.
ID system interface module.
ID controller M-688-001/002 BIS can be installed directly to the Q series of substrates,
Control module for reading and writing ID tag data through a programmable logic controller.
The ladder diagram of M-688-002 BIS is compatible with QD35ID1/2 Q173NCCPU Common Instructions Manual Q173NCCPU Programming Manual.
2 antennas can be connected, and the parallel processing of the 2 channels can be simultaneously carried out
Q173NCCPU
Can use all ID tags in the M BIS series.
ID series /BIS system is an industrial automation ID system which can use the electromagnetic combination method to read and write data.
ID tag has a variety of sizes and storage capacity.Program capacity: 60 K step.
Input / output points: 4096 points Q173NCCPU Common Instructions Manual Q173NCCPU Programming Manual.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 240 KB.
Support USB and RS232.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.
Ultra high speed processing, production time is shortened, better performance.
As applications become larger and more complex, it is necessary to shorten the system operation cycle time Q173NCCPU Common Instructions Manual Q173NCCPU Programming Manual.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias.Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to tthe condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces Q173NCCPU Common Instructions Manual Q173NCCPU Programming Manual.
Visualization of installation status.
Can monitor the safe output,, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start Q173NCCPU Common Instructions Manual Q173NCCPU Programming Manual.