1582此ID下载地址不存在3--/downloadfile/36-MELSEC-QLQnA-Programming-(PID-Control-88s).pdf MITSUBISHI Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual

MITSUBISHI Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual

Brand: MITSUBISHI
Product model: Q173DSCPU
Name: PLC
Sort: Programming Manual (PID Control Instructions)
File language: English
File size: 0.00MB
Q3MEM-8MBS, Q3MEM-4MBS replacement battery.FL-net (OPCN-2) Ver.2.00 interface.
10BASE5/10BASE-T use.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module.
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual Q173DSCPU
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value.
Easy connection programming tool via ethernet Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual. PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF iinformation) and word data (such as analog information) Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q173DSCPU PID Control Instructions Manual Q173DSCPU Programming Manual.
Even if the information reaches saturation, it will not affect the link scan time.
Related products
MITSUBISHI
Motion controller
Q172DSCPU
MITSUBISHI Motion controller Q172DSCPU
Control axis: up to 16 axes. Servo amplifier
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching opera
MITSUBISHI
CPU unit
A2ASCPU
MITSUBISHI CPU unit A2ASCPU
I/O points: 512. Processing speed: sec/ 0.2u
MITSUBISHI
Manual pulse generator interface module
Q173PX
MITSUBISHI Manual pulse generator interface module Q173PX
Manual pulse generator /INC synchronous encod