Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost Q173CPUN Structured Text Manual Q173CPUN Programming Guide.
The performance of the cycle data update is improved Q173CPUN
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish the network can handle large capacity data.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station Q173CPUN Structured Text Manual Q173CPUN Programming Guide. Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O Q173CPUN Structured Text Manual Q173CPUN Programming Guide.
QJ61CL12 can be used as the main station of CC-Link/LT.Input / output points: 256 points.
Program capacity: 8 K step.
Processing speed: 0.2 s.
Built in communication port: RS232*1.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.Input points: 16 points.
Input voltage and current: 8mA AC100-120V (AC100V; 60Hz) /7mA (AC100V; 50Hz).
Response time: 20ms.
16 points / a common end.
18 point spring clip connection terminal.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connecttion (1 to 1),
No need to carry out the IP address settings Q173CPUN Structured Text Manual Q173CPUN Programming Guide. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q173CPUN Structured Text Manual Q173CPUN Programming Guide.
Related products
MITSUBISHI
Motion CPU module
Q173HCPU-T
MITSUBISHI Motion CPU module Q173HCPU-T
Control axis: maximum 32 axes. Teaching runni
MITSUBISHI
CNC numerical control CPU
Q173NCCPU-S01
MITSUBISHI CNC numerical control CPU Q173NCCPU-S01
Set high performance CNC and high speed progr
MITSUBISHI
Motion controller
Q173DSCPU
MITSUBISHI Motion controller Q173DSCPU
Control axis: up to 32 axes. Servo amplifier
MITSUBISHI
Manual pulse generator interface module
Q173PX
MITSUBISHI Manual pulse generator interface module Q173PX
Manual pulse generator /INC synchronous encod