1827此ID下载地址不存在3--/downloadfile/95-Structured-Text-(ST)-Programming--Book.pdf MITSUBISHI Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book

MITSUBISHI Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book

Brand: MITSUBISHI
Product model: Q13UDHCPU
Name: PLC
Sort: Programming Guide Book (Structured Text)
File language: English
File size: 0.00MB
Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book Q13UDHCPU
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network.
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data update is improved.
The transmission delay time is shoortened, and the synchronous waiting time of the application can be shortened Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish thee network can handle large capacity data Q13UDHCPU Structured Text Manual Q13UDHCPU Programming Guide Book.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station.
Related products
MITSUBISHI
General purpose CPU
Q26UDHCPU
MITSUBISHI General purpose CPU Q26UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General purpose CPU
Q10UDHCPU
MITSUBISHI General purpose CPU Q10UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q50UDEHCPU
MITSUBISHI With Ethernet CPU Q50UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Numer of