Battery replacement.
Initial voltage 3.0V.
Current capacity: 5000mAh.
Service life: 5 years."1 axes, SSCNET connection type.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc Maintenance and Inspection Manual Q13UDEHCPU User's Manual Q13UDEHCPU .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug.
Saving wiring through SSCNET cable connections while simultaneously,
The length of the total cable distance up to 30m Maintenance and Inspection Manual Q13UDEHCPU User's Manual.
In addition, an absolute position system for determining the origin position is supported by the return data set operation of the origin.
No need for the near point block, such as wiring. "PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Maintenance and Inspection Manual Q13UDEHCPU User's Manual.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
Province distribution network module in cabiinet and device Q13UDEHCPU Hardware Design.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Linkk/LT from the station does not need any parameter settings Q13UDEHCPU Hardware Design.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
Related products
MITSUBISHI
General purpose CPU
Q13UDHCPU
MITSUBISHI General purpose CPU Q13UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q100UDEHCPU
MITSUBISHI With Ethernet CPU Q100UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Numer of