MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual

MITSUBISHI Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual

Brand: MITSUBISHI
Product model: Q13DUVCPU
Name: PLC
Sort: Programming Manual (Application Functions)
File language: English
File size: 5.25MB
SI/QSI/H-PCF/ broadband H-PCF optical cable.
Double circuit.
Remote I/O network (remote I/O station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual Q13DUVCPU
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Input: 4 channels.
Thermocouple (C1602~1995 JIS).
Micro voltage (-100mV~100mV).
Conversion speed: (sampling period x3) /1 channel.
18 point terminal station.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameterss, procedures, etc Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q13DUVCPU Application Functions Manual Q13DUVCPU Programming Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Related products
MITSUBISHI
General high speed CPU
Q06UDVCPU
MITSUBISHI General high speed CPU Q06UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General high speed CPU
Q26UDVCPU
MITSUBISHI General high speed CPU Q26UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General high speed CPU
Q04UDVCPU
MITSUBISHI General high speed CPU Q04UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
CPU unit
A3VCPU
MITSUBISHI CPU unit A3VCPU
Multiple CPU units for A3VTS multiplex system