8 slots.
The main substrate needs to be equipped with CPU and power supply.
Requires 1 power modules.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q12PRHCPU Structured Text Manual Q12PRHCPU Programming Manual
Q12PRHCPU
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.GI-50/125 optical cable.
Double ring Q12PRHCPU Structured Text Manual Q12PRHCPU Programming Manual.
Remote I/O net (remote master station).
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized Q12PRHCPU Structured Text Manual Q12PRHCPU Programming Manual.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the sett value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q12PRHCPU Structured Text Manual Q12PRHCPU Programming Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q12PRHCPU Structured Text Manual Q12PRHCPU Programming Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.