8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc Q12DCCPU-CBL Special Instructions Manual Q12DCCPU-CBL Strctured Programming Manual. .
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored Q12DCCPU-CBL
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost Q12DCCPU-CBL Special Instructions Manual Q12DCCPU-CBL Strctured Programming Manual.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change Q12DCCPU-CBL Special Instructions Manual Q12DCCPU-CBL Strctured Programming Manual.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value).
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored. Control axis: up to 16 axes.
Interpolation function: linear interpolation (maximum 4 axis), arc interpolation (2 axis), spiral interpolation (3 axis).
PLC capacity: 60K step.
Can control the maximum 16 axis servo amplifier.
With the position control, speed control, torque control, advanced synchronous control and other rich control methods.
The incremental synchronous encoder I/F and the symbol detection signal I/F are integrated in the 1 modules.
Capacity expansion can be expanded to PLC capacity 60K step (using Q170MSCPU-S1), the 7 layer of the substrate. Q12DCCPU-CBL Special Instructions Manual Q12DCCPU-CBL Strctured Programming Manual.
Combined with the servo amplifier to achieve safe torque off (STO).
Connect directly to the visual system produced by Ethernet through the COGNEX connection.
Connecction SSCNET III /H main module LJ72MS15 can use the MELSEC-L series of input Q12DCCPU-CBL Special Instructions Manual Q12DCCPU-CBL Strctured Programming Manual.
Output module, analog input and output module, high speed counter module.