Q series of basic conversion module, A series of additional basic unit connection adapter unit.
Suitable for: A5 - B/A6 - B.2 axes, open collector output type.
2 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
Maximum pulse output: 200Kpps Q06HCPU MELSAP-L Manual Q06HCPU Programming Manual.
40 pin connector.
Positioning module
Q06HCPU
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q06HCPU MELSAP-L Manual Q06HCPU Programming Manual.
(the command pulse of the open collector positioning module is highest 200kpps.) 8 slots.
The main substrate needs to be equipped with CPU and power supply.
Support for high speed communication between multi CPU.
Requires 1 power modules.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location Q06HCPU MELSAP-L Manual Q06HCPU Programming Manual.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.PCI bus.
Support Japanese, English OS.
GI optical cable.
Dual loop controller network (control station / common station).
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information).
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time Q06HCPU MELSAP-L Manual Q06HCPU Programming Manual.
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability.
The transmission distance of 50m/200m/1km/3km can be selectted Q06HCPU MELSAP-L Manual Q06HCPU Programming Manual.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.