1352此ID下载地址不存在3--/downloadfile/34-MELSEC-QL-Structured-Programming-(Common-88s).pdf MITSUBISHI Q06HCPU Common Instructions Manual Q06HCPU Programming Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06HCPU Common Instructions Manual Q06HCPU Programming Manual

MITSUBISHI Q06HCPU Common Instructions Manual Q06HCPU Programming Manual

Brand: MITSUBISHI
Product model: Q06HCPU
Name: PLC
Sort: Programming Manual (Common Instructions)
File language: English
File size: 0.00MB
Q series of basic conversion module, A series of additional basic unit connection adapter unit.
Suitable for: A5 - B/A6 - B.4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel.
18 point terminal station.
Isolation between channels Q06HCPU Common Instructions Manual Q06HCPU Programming Manual.
The possibility of expanding control with intelligent function Q06HCPU
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q06HCPU Common Instructions Manual Q06HCPU Programming Manual.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules Q06HCPU Common Instructions Manual Q06HCPU Programming Manual.
Using the inter channel isolation analog module.Input points: 32 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 point /1 a public side.
Common anode.
40 pin connector.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbbers, but also the use of special characters,
To further enhance the security of the password Q06HCPU Common Instructions Manual Q06HCPU Programming Manual.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorizeed access to unauthorized users Q06HCPU Common Instructions Manual Q06HCPU Programming Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Related products
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral I/F:
MITSUBISHI
CPU component
A1SHCPU
MITSUBISHI CPU component A1SHCPU
I/O control method: refresh mode or direct mo
MITSUBISHI
Motion controller
Q173DSCPU
MITSUBISHI Motion controller Q173DSCPU
Control axis: up to 32 axes. Servo amplifier