MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual

MITSUBISHI Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual

Brand: MITSUBISHI
Product model: Q06HCPU-A
Name: PLC
Sort: Programming Manual (PID Control Instructions)
File language: English
File size: 3.33MB
PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual Q06HCPU-A
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2 Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual. 5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.Output: 6 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000.
Output: DC-12V~12V; 0~22mA.
Conversion speed: 6ms/ channel.
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module. Q06HCPU-A PID Control Instructions Manual Q06HCPU-A Programming Manual.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
Related products
MITSUBISHI
A mode Q series CPU
Q02CPU-A
MITSUBISHI A mode Q series CPU Q02CPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
High performance CPU
Q06HCPU
MITSUBISHI High performance CPU Q06HCPU
Program capacity: 60 K step. Input / output p
MITSUBISHI
A mode Q series CPU
Q06HCPU-A
MITSUBISHI A mode Q series CPU Q06HCPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Numer of