Q2MEM-1MBS and Q2MEM-2MBS replacement batteries.Control axis: maximum 8 axes.
Greater flexibility.
PLC control and motion control using independent CPU, optimize the system configuration.
More than 4 CPU modules can be freely selected in multi CPU system.
MITSUBISHI SSCNET control function.
By using the high speed serial communication mode, we can easily construct the synchronization system of the servo motor Q03UDECPU Structured Text(ST) Manual Q03UDECPU PROGRAMMING Guide Book Q03UDECPU
The motion controller and the servo amplifier can be quickly connected by a connector, and the connection is simplified.
Each 1 CPU can control up to 32 axes at the same time.
Can control the small capacity from 10W to 55KW large capacity servo motor.
Through the use of digital oscilloscope function, can be used to control the power distance, speed, position and other motor information monitoring Q03UDECPU Structured Text(ST) Manual Q03UDECPU PROGRAMMING Guide Book. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module Q03UDECPU Structured Text(ST) Manual Q03UDECPU PROGRAMMING Guide Book.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value att the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q03UDECPU Structured Text(ST) Manual Q03UDECPU PROGRAMMING Guide Book.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q03UDECPU Structured Text(ST) Manual Q03UDECPU PROGRAMMING Guide Book.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Related products
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
General purpose CPU
Q03UDCPU
MITSUBISHI General purpose CPU Q03UDCPU
Input / output points: 4096 points. Numer of