Express PCI bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
With external power supply function.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs Q02PHCPU MELSAP-L Manual Q02PHCPU Programming Manual
Q02PHCPU
High speed communication capable of communicating with 1Gbps.
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller Q02PHCPU MELSAP-L Manual Q02PHCPU Programming Manual.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station Q02PHCPU MELSAP-L Manual Q02PHCPU Programming Manual.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.DC5V DC current consumption: 0.23A.
Number of I/O modules can be installed: 8.
Program capacity: 8K step.
Input / output points: 256 points.
Number of input and output elements: 2048.
Power +8 tank bottom plate of the CPU.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registeered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users Q02PHCPU MELSAP-L Manual Q02PHCPU Programming Manual.
Therefore, it is important to prevent the outflow of important program assets and protect intellectuual property rights Q02PHCPU MELSAP-L Manual Q02PHCPU Programming Manual.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register.