Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q02HCPU-A Fundamentals Manual Q02HCPU-A Strctured Programming Manual
Q02HCPU-A
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program Q02HCPU-A Fundamentals Manual Q02HCPU-A Strctured Programming Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q02HCPU-A Fundamentals Manual Q02HCPU-A Strctured Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: P type (positive public end / positive public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features.
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces Q02HCPU-A Fundamentals Manual Q02HCPU-A Strctured Programming Manual.
Visualization of installation status.
Can monitor the safe output,, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start Q02HCPU-A Fundamentals Manual Q02HCPU-A Strctured Programming Manual.