991此ID下载地址不存在3--/downloadfile/30-MELSEC-QL-Programming-(MELSAP-L).pdf MITSUBISHI Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual

MITSUBISHI Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual

Brand: MITSUBISHI
Product model: Q02CPU-A
Name: PLC
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 0.00MB
Three-phase 4 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual Q02CPU-A
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual.
3 phase 3 wire products can be used to measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products.
For example, a module can be used to measure other loads from the control panel trunk Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.Input voltage range: AC100-120V.
Output voltage: DC5V.
Output power: 6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parammeters due to forgetting to replace the battery Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q02CPU-A MELSAP-L Manual Q02CPU-A Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.
Related products
MITSUBISHI
A mode Q series CPU
Q06HCPU-A
MITSUBISHI A mode Q series CPU Q06HCPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
High performance CPU
Q02CPU
MITSUBISHI High performance CPU Q02CPU
Program capacity: 28K step. Input / output po
MITSUBISHI
A mode Q series CPU
Q02CPU-A
MITSUBISHI A mode Q series CPU Q02CPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Numer of