MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual

MITSUBISHI Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual

Brand: MITSUBISHI
Product model: Q02CPU-A
Name: PLC
Sort: Programming Manual (Application Functions)
File language: English
File size: 5.25MB
Control axis: up to 16 axes.
Interpolation function: linear interpolation (maximum 4 axis), arc interpolation (2 axis), spiral interpolation (3 axis).
PLC capacity: 60K step.
Can control the maximum 16 axis servo amplifier.
With the position control, speed control, torque control, advanced synchronous control and other rich control methods Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual Q02CPU-A
The incremental synchronous encoder I/F and the symbol detection signal I/F are integrated in the 1 modules.
Capacity expansion can be expanded to PLC capacity 60K step (using Q170MSCPU-S1), the 7 layer of the substrate.
Combined with the servo amplifier to achieve safe torque off (STO).
Connect directly to the visual system produced by Ethernet through the COGNEX connection Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual.
Connection SSCNET III /H main module LJ72MS15 can use the MELSEC-L series of input.
Output module, analog input and output module, high speed counter module.Adapter for mounting DIN guide rail.
For Q38B-E, Q312B-E, Q612B, Q38RB, Q68RB, Q65WRB, Q38DB, Q312DB.The telephone line of the interface module is connected with the peripheral equipment.Input: 4 channels.
Thermocouple (C1602~1995 JIS) Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual.
Micro voltage (-100mV~100mV).
Conversion speed: (sampling period x3) /1 channel.
18 point terminal station.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameteers, procedures, etc Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q02CPU-A Application Functions Manual Q02CPU-A Programming Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Related products
MITSUBISHI
A mode Q series CPU
Q02CPU-A
MITSUBISHI A mode Q series CPU Q02CPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
High performance CPU
Q02CPU
MITSUBISHI High performance CPU Q02CPU
Program capacity: 28K step. Input / output po
MITSUBISHI
A mode Q series CPU
Q06HCPU-A
MITSUBISHI A mode Q series CPU Q06HCPU-A
Input / output points: 4096 points. Numer of
MITSUBISHI
A mode Q series CPU
Q02HCPU-A
MITSUBISHI A mode Q series CPU Q02HCPU-A
Input / output points: 4096 points. Numer of