1165此ID下载地址不存在3--/downloadfile/32-MELSEC-QL-Serial-Communicationxxd-(Application).pdf MITSUBISHI Q01CPU Application Manual Q01CPU User's Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q01CPU Application Manual Q01CPU User's Manual

MITSUBISHI Q01CPU Application Manual Q01CPU User's Manual

Brand: MITSUBISHI
Product model: Q01CPU
Name: PLC
Sort: User's Manual (Application)
File language: English
File size: 0.00MB
Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q01CPU Application Manual Q01CPU User's Manual Q01CPU
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program Q01CPU Application Manual Q01CPU User's Manual.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion Q01CPU Application Manual Q01CPU User's Manual.
The next time the power is turned on, the backup data will be automatically restored.Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits.
Insulation monitoring module for measuring leakage current.
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program. Alarm monitoring is divided into 2 stages of attention alarm and danger alarm Q01CPU Application Manual Q01CPU User's Manual.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement.
Inn addition, Works2 GX (1 Q01CPU Application Manual Q01CPU User's Manual. 90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).
Related products
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching opera
MITSUBISHI
CPU component
A1SHCPU
MITSUBISHI CPU component A1SHCPU
I/O control method: refresh mode or direct mo