Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program Q00UJCPU-SET Application Functions Manual Q00UJCPU-SET Strctured Programming Manual
Q00UJCPU-SET
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment Q00UJCPU-SET Application Functions Manual Q00UJCPU-SET Strctured Programming Manual. Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q00UJCPU-SET Application Functions Manual Q00UJCPU-SET Strctured Programming Manual.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to repllace the battery Q00UJCPU-SET Application Functions Manual Q00UJCPU-SET Strctured Programming Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q00UJCPU-SET Application Functions Manual Q00UJCPU-SET Strctured Programming Manual.
The next time the power is turned on, the backup data will be automatically restored.