MES interface module.
Need MX MESInterface software and CF card.
Easily connect production equipment and information system.
Through the excellent database sharing function, greatly reduce the cost of information.
By direct connection, the connection process of the enterprise system database (such as MES) is simplified Q00JCPU Fundamentals Manual Q00JCPU Strctured Programming Manual.
Module configuration is simple, without any programming
Q00JCPU
The data can be monitored in the module side, when a user defined trigger condition occurs,
Will be read in the form of SQL text and send the specified data to the MES.
The network load can be reduced compared with the previous scheme which is based on the gateway PC to obtain / monitor the data.
Receive information from the MES, perform pre stored SQL tasks Q00JCPU Fundamentals Manual Q00JCPU Strctured Programming Manual.
In addition, the production instructions from the MES are also received,
The production information can be downloaded from the database, and the modification of the formula information can be conveniently carried out. Upgraded version.
Control axis: maximum 32 axes.
Manual pulse generator operation function: can use 3 sets of manual pulse generator.
Synchronous encoder operation function: can use 12 synchronous encoder Q00JCPU Fundamentals Manual Q00JCPU Strctured Programming Manual.
Peripheral I/F: by CPU PLC.
High speed motion control system based on multi CPU architecture.
Multi CPU system based on Q series PLC.
Flexible selection of CPU PLC and motion CPU according to different applications.
In the construction of multi CPU system, can have up to 4 sets of CPU.
When 3 Q173DCPU is used, the maximum 96 axes can be controlled.Input and output points: 512 points.
Input / output data points: 8192 points.
Program capacity: 28k.
Basic command processing speed (LD command) S:0.2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The conttents of the output status register are changed with the execution of the program Q00JCPU Fundamentals Manual Q00JCPU Strctured Programming Manual.
Output refresh phase: when all instructions are executed,
The output status register is sent to the ooutput latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment Q00JCPU Fundamentals Manual Q00JCPU Strctured Programming Manual.