MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI LM-U2 Manual LM-U2 INSTRUCTION MANUAL

MITSUBISHI LM-U2 Manual LM-U2 INSTRUCTION MANUAL

Brand: MITSUBISHI
Product model: LM-U2
Name: SSCNET Compatible Linear Servo
Sort: INSTRUCTION MANUAL
File language: English
File size: 5.24MB
Output points: 64 points.
Output form: source type.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have.
Common way: 32 point / public end.
Input / output occupied points: 64 points (I/O distribution: output 64 points).
External wiring connection: 40 pin connector two LM-U2 Manual LM-U2 INSTRUCTION MANUAL.
The switch input and output module is a device which can collect the input / output of the switch signal,
Digital I/O modules are often called LM-U2
The switch signal is collected to the computer or the computer to send the relevant instructions through the RS-485 bus to control the switch of the switch,
Can also be carried out through the RS-485 bus communication,
Remote control switch.
Communication protocol is a standard Modbus protocol or custom protocol LM-U2 Manual LM-U2 INSTRUCTION MANUAL. SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H module.
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space LM-U2 Manual LM-U2 INSTRUCTION MANUAL.
In addition, the module can be used for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed. Differential output.
Axis of control: 2.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start.
The use of steps in accordance with the auxiliary function can be.
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be ddisplayed in real time LM-U2 Manual LM-U2 INSTRUCTION MANUAL.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check.
Can only choose the necessary items from the rich monitoring information and monitor the display LM-U2 Manual LM-U2 INSTRUCTION MANUAL.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action.
Related products
MITSUBISHI
Resist film
GT10-40PSGB
MITSUBISHI Resist film GT10-40PSGB
Protective film for 4.7 inch screen. Scru, 5
MITSUBISHI
Resist film
GT11-50PSGW
MITSUBISHI Resist film GT11-50PSGW
Protective film for 5.7 inch screen. Scru f
MITSUBISHI
USB protective film
GT16-UCOV
MITSUBISHI USB protective film GT16-UCOV
USB interface protection cover on the front p
MITSUBISHI
Resist film
GT16-70PSGW
MITSUBISHI Resist film GT16-70PSGW
Protective film for 10.4 inch screen. Scru