SSCNET III /H remote station.
Transmission speed: 150Mbps.
End cap.
Play the role of SSCNET III /H remote station
SSCNET III /H host module is the MELSEC-L series of input and output modules and intelligent function modules connected to the SSCNET III /H module.
Can be used as a remote station of motion controller,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space LJ71C24-R2 Basic Manual LJ71C24-R2 User's Manual
LJ71C24-R2
In addition, the module can be used for the input and output of the motion controller by the circulating transmission, and the module of the SSCNET III /H host module can be installed. RS-232.
Transmission speed: 230.4kbps.
MC protocol.
Communication protocol support function LJ71C24-R2 Basic Manual LJ71C24-R2 User's Manual.
Can only be used on the ch1 side.
Device for immediate communication
Communication protocol support function through Works2 GX,
Can easily set the required agreement with the other equipment communication.
In addition, only the communication protocol library is required to select the equipment to be carried out,
Immediate connection.
The creation and editing of communication protocols are simple and easy to implement, even if there is no connection equipment in the communication protocol library,
Can also simply create a corresponding protocol for communication LJ71C24-R2 Basic Manual LJ71C24-R2 User's Manual.
The content of the communication protocol that can be created in the list,
Can also be simply edited. Input points: 16 points.
Rated input voltage: DC24V.
Common way: 16 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the parrt can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on LJ71C24-R2 Basic Manual LJ71C24-R2 User's Manual LJ71C24-R2 Basic Manual LJ71C24-R2 User's Manual.