MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual

MITSUBISHI L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual

Brand: MITSUBISHI
Product model: L26CPU-BT-CM
Name: PLC
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 3.16MB
Open collector output.
Axis of control: 4.
Maximum output pulse: pulse/s 200k.
Location data: 600 data / axis.
Max link distance: 2m.
With the parameter setting, the synchronization control can be easily realized. Do not need to write complex procedures.
Start / stop with synchronous control of the shaft L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual.
Synchronous control of the axis and the positioning of the axis can coexist L26CPU-BT-CM
Through the clutch, the movement of the main shaft can be transferred to the output shaft.
Simple implementation of synchronization control.
Cam control is more simple
Cam data can easily create a variety of patterns.
Can be simple to achieve the gear, shaft, transmission, cam and other mechanical mechanisms to replace the software synchronization control L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual.
It is not subject to the limitation of the concept of the electronic cam control so far, and can use the cam with high degree of freedom.
The stroke, speed, acceleration and beat can be confirmed on the graph, and the setting is carried out at the same time.
Can also be through the cam data thumbnail display, easy to confirm the cam data has been created L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual.
Can import and export the cam data in CSV format. Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence).
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isoolation L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convennient and flexible L26CPU-BT-CM MELSAP-L Manual L26CPU-BT-CM Programming Manual.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability.
Related products
MITSUBISHI
cpu module
L26CPU-P
MITSUBISHI cpu module L26CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L26CPU-BT-CM
MITSUBISHI cpu module L26CPU-BT-CM
"Universal output function: leakage type. Pro