1251此ID下载地址不存在3--/downloadfile/32-MELSEC-QL-Serial-Communicationxxd-(Application).pdf MITSUBISHI L06CPU-P Application Manual L06CPU-P User's Manual - MITSUBISHI
MITSUBISHI
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L06CPU-P Application Manual L06CPU-P User's Manual

MITSUBISHI L06CPU-P Application Manual L06CPU-P User's Manual

Brand: MITSUBISHI
Product model: L06CPU-P
Name: PLC
Sort: User's Manual (Application)
File language: English
File size: 0.00MB
Input points: 8 points.
Rated input voltage: AC100 ~ 120V.
Common way: 8 point / public end.
Input / output occupied points: 16 points (I/O distribution: 16 points).
External wiring connection: 18 point terminal.
The input and output module is also called control module, which can output signal when there is control requirement,
Or provide a switch signal to the controlled device,
At the same time, the feedback signal of the equipment can be received to report to the host computer,
Is an important part of the fire alarm linkage system,
The input and output modules in the market can provide a pair of passive normally open / normally closed contacts,
For controlling the controlled equipment, the module of the part can be set by the parameters,
Set to active output, corresponding to the two input and output modules, multiple input and output modules, and so on L06CPU-P Application Manual L06CPU-P User's Manual L06CPU-P Application Manual L06CPU-P User's Manual L06CPU-P "Universal output function: source type.
Program capacity: 20K step.
Basic operations processing speed: 40ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation.
Input / output points: 1024 points L06CPU-P Application Manual L06CPU-P User's Manual.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PPWM control of the highest 200kHz L06CPU-P Application Manual L06CPU-P User's Manual.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s.
In addition to lighting dimming coontrol, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators L06CPU-P Application Manual L06CPU-P User's Manual. "
Related products
MITSUBISHI
cpu module
L02SCPU-P
MITSUBISHI cpu module L02SCPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-PBT
MITSUBISHI cpu module L26CPU-PBT
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L02CPU-P
MITSUBISHI cpu module L02CPU-P
"Universal output function: source type. Prog